Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.077
Filtrar
1.
Acta Stomatol Croat ; 58(1): 18-29, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38562221

RESUMO

Objectives: To compare three different orthodontic adhesives (Transbond XT Light Cure Adhesive, Heliosit Orthodontic, Fuji Ortho LC) bonded to two types of orthodontic brackets: ceramic brackets (Fascination Roth 0.22) and metallic brackets (Topic Roth 0.22, Dentaurum). Materials and methods: The study was performed on 18 human teeth (6 for each adhesive). The prepared teeth were divided into three groups according to the examination time. Subsequently, they were observed after 1, 2 and 3 weeks following bonding. After the experimental procedure, the teeth samples were cut in half along the longitudinal axis in the vestibulo-oral direction, fixed with conductive carbon cement, placed in a high-vacuum evaporator and then coated with carbon. One half of each sample was observed under a Field-emission gun scanning electron microscope (FEG-SEM Hitachi SU 8030, Japan), while on the second half of the samples qualitative (X-ray line-scans) and semi-quantitative point X-ray energy dispersive analyses (EDX) were performed with Thermo Noran (USA) NSS System 7, equipped with Ultra Dry detector (30 mm2 window). Results: Transbond XT had an ideal bond with the enamel and the bracket base, with rare presence of microgaps and cracks in the enamel. Heliosit Orthodontic demonstrated a better bond relationship with the bracket base than the enamel, whereas in the latter the presence of microgaps in the bond was observed. The microphotographs of Fuji Ortho LC demonstrated many cracks inside the adhesive, and some of them continued to move forward into the enamel surface. Therefore, an impression of a very solid bond relationship with the enamel exists, with cracks being present in the enamel surface and never at the enamel-adhesive interface. Microgaps also appeared at the bracket-adhesive interface. Conclusion: Transbond XT is a highly filled composite resin and is an ideal orthodontic adhesive in each aspect examined, with an ideal enamel-adhesive and bracket-adhesive interface. Heliosit Orthodontic provides better bracket-adhesive interface compared to the enamel. Fuji Ortho LC as a solid resin-modified GIC provides a better enamel-adhesive interface, compared to the bracket base.

2.
J Pharm Bioallied Sci ; 16(Suppl 1): S427-S430, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595483

RESUMO

Background: Surface roughness and hardness are key factors that influence the clinical performance and durability of denture teeth. Understanding variations in these properties among different denture teeth materials can assist in selecting the most suitable materials for optimal patient outcomes. This study aimed to investigate the surface roughness and hardness of four commonly used denture teeth materials: acrylic resin, composite resin, porcelain, and nanohybrid composite. Materials and Methods: Ten specimens were prepared for each denture teeth material, resulting in a total of 40 specimens. Surface roughness was assessed using a profilometer, and measurements were recorded in micrometers (µm). Hardness was determined using a Vickers hardness tester, and results were expressed as Vickers hardness numbers (VHN). The surface roughness and hardness data were analyzed using appropriate statistical tests (e.g., analysis of variance), with significance set at P < 0.05. Results: The results revealed significant differences in both surface roughness and hardness among the different denture teeth materials (P < 0.05). Acrylic resin exhibited the highest surface roughness (mean ± standard deviation: 3.45 ± 0.78 µm) and the lowest hardness (mean ± standard deviation: 45.6 ± 2.3 VHN). Composite resin demonstrated intermediate values of surface roughness (mean ± standard deviation: 1.87 ± 0.54 µm) and hardness (mean ± standard deviation: 65.2 ± 3.9 VHN). Porcelain demonstrated the smoothest surface (mean ± standard deviation: 0.94 ± 0.28 µm) and the highest hardness (mean ± standard deviation: 78.5 ± 4.1 VHN). Nanohybrid composite displayed surface roughness and hardness values similar to composite resin. Conclusion: This study demonstrated significant variations in surface roughness and hardness among the different denture teeth materials evaluated. Acrylic resin exhibited the roughest surface and lowest hardness, while porcelain demonstrated the smoothest surface and highest hardness. Composite resin and nanohybrid composite exhibited intermediate values. These findings provide valuable insights for prosthodontic practitioners in selecting denture teeth materials based on specific clinical requirements, aiming to achieve optimal aesthetics, reduced plaque accumulation, and improved wear resistance.

3.
Gen Dent ; 72(3): 42-48, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38640005

RESUMO

The present article reviews the literature regarding tetracycline staining of the dentition and its esthetic management. A total of 49 articles were identified in the initial search, and 22 articles met the eligibility criteria of this narrative literature review. Tetracycline staining results from its use in children between the ages of 6 months and 6 years, when tooth crowns are formed; the effects are dependent on the dosage, duration of treatment, stage of tooth mineralization, and activity of the mineralization process. Tooth bleaching is always the first treatment option for low-grade cases of tetracycline staining. Restorative procedures are indicated for severe staining. The article also describes the treatment of severe staining affecting the maxillary anterior dentition of a 48-year-old man who reported the systemic administration of tetracycline during childhood. Direct composite resin laminate veneers were proposed to achieve immediate, highly esthetic restorations. A combination of different resinous materials in different shades was applied to meet the needs of the patient. The use of direct composite resin laminate veneers satisfied the functional and esthetic demands of the patient at a lower cost than ceramic materials.


Assuntos
Porcelana Dentária , Dentição , Humanos , Masculino , Pessoa de Meia-Idade , Antibacterianos , Resinas Compostas , Facetas Dentárias , Tetraciclina/efeitos adversos
4.
J Hist Dent ; 72(1): 27-35, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38642377

RESUMO

A full account of the preceded early research tribulation that led to the development of the first visible light activated composite resin and the first visible light activator source is documented. The events took place over four years since early 1974 when a raw industrial composite resin that was radiolucent, stiff paste, universal optically opaque white color, polymerized by exposure to a prototype visible light for 120 seconds was given to developed. Four years later, the developed restorative composite resin ended up as a radiopaque, optically translucent, universal color with an additional three shades that possessed the biologic, esthetic, mechanical and physical characteristics with proven efficacy be used for esthetic zone. This conservative account of early development of a technology that must count as one of a small number of inventions during the seventies, over the years has revolutionized restorative dental practice. We were privileged and very lucky to be associated with developmental stages, stumbling blocks, and final success of the first LC Composite resin that ignited the thought process worldwide and laid the foundation for modern esthetic restoratives practiced today.


Assuntos
Aminas , Resinas Compostas , Estética Dentária , Odontologia , Tecnologia
5.
Cureus ; 16(4): e58544, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38644945

RESUMO

Nanotechnology is extensively employed in various aspects of dentistry, including restorative dentistry, because of its substantial improvement and promising potential in the clinical efficacy of restorative materials and procedures. The main purpose of this review is to explore the different uses of nanomaterials in restorative dentistry. The review is divided into two parts: the current review (Part 1) focuses on the prevention of demineralization and promotion of remineralization, while the upcoming review (Part 2) will discuss the reinforcement of restorative materials and their therapeutic applications. Nanofillers are added to dental materials to boost their antibacterial, anticaries, and demineralization inhibitory capabilities. Additionally, they improve remineralization and enhance both mechanical properties and therapeutic features. The nanoparticles (NPs) used to increase antibacterial and remineralization inhibitions can be classified into two main groups: inorganic and organic NPs. Examples of inorganic NPs include silver, zinc oxide, titanium oxide, and gold. Examples of organic NPs include silica, quaternary ammonium salt monomers, and chitosan NPs. Furthermore, the nanofillers utilized to enhance the process of remineralization include various types such as metals, nano-hydroxyapatite, nano-amorphous calcium phosphate (ACP), dicalcium phosphate NPs, casein phosphopeptide-ACP (CPP-ACP), and calcium fluoride NPs. These uses underscore the potential applications of NPs in restorative dentistry, although there are still some limitations to address.

6.
J Conserv Dent Endod ; 27(3): 321-325, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38634032

RESUMO

Background: Anterior tooth discolorations can be treated conservatively and noninvasively through bleaching to achieve the desired esthetic outcomes. However, bleaching along with composite resin is advisable for certain clinical cases for optimum results. However, shear bond strength (SBS) of composite resin to the bleached tooth gets significantly lowered. Before placing the composite restoration, the bleached enamel needs to be treated with antioxidant agents to increase its SBS. The study aims to evaluate and compare the effect of herbal antioxidants on SBS of composite resin to bleached enamel at different time intervals. Materials and Methods: Sixty extracted single-rooted maxillary incisors postdecoronation, keeping their labial surfaces up were mounted in cold-cure acrylic resin. The samples were randomly divided into: Group I - unbleached; Group II - 10% pine bark extract for 10 min postbleaching; Group III - 10% pine bark extract for 20 min postbleaching; Group IV - application of 10% rosemary extract for 10 min postbleaching, Group V - application of 10% rosemary extract for 20 min postbleaching; Group VI - no application of antioxidant. 35% hydrogen peroxide was used for bleaching all the samples except those which served as negative control. Later composite cylinder 4 mm in diameter and length were built on prepared enamel. The maximum load at failure was recorded using the universal testing machine. Statistical Analysis: Data were analyzed using the analysis of variance and Tukey's t-test with significance level of P < 0.05. Results: Highest load was exhibited by Group I. Group V showed satisfactory shear strength followed by Groups IV, III, II, and VI. Conclusion: Both 10% rosemary and 10% pine bark extracts showed better results when applied for 20 min as compared to 10 min application. Increased duration of antioxidant application increases the SBS.

7.
J Dent ; 145: 105009, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643866

RESUMO

OBJECTIVES: Resin-based composites (RBCs) evolved into favoured materials for teeth restorations, marking a significant change in dental practice. Despite many advantages, RBCs exhibit various limitations in their physical and chemical properties. Therefore, we assessed the dentists' awareness of possible complications after direct composite restorations and their opinions about this material. METHODS: The online questionnaire was created in English in May 2023. A 16-item survey was dedicated to general dentists and specialists. The first section included four questions related to demographic characteristics. The second section comprised twelve questions and focused on awareness of potential side effects of composite restorations, the most crucial advantages and disadvantages of composite resins, and the frequency of experienced clinical complications after the application of composite materials. RESULTS: A total of 1830 dentists from 13 countries took part in the survey. Dentists most often declared awareness of low adhesion to the dentine (77.5 %) and, most rarely, solubility in oral fluids (42.6 %). Aesthetics was identified as the main advantage of composite fillings (79 %), followed by the possibility of repair (59 %) and adhesion to enamel (57 %). Polymerisation shrinkage was a major disadvantage for most countries (70 % overall). Analysing the declared potential clinical complications for all countries, statistically significant findings were obtained for marginal discolouration (OR=2.982, 95 % CI: 1.321-6.730, p-value=0.009) and borderline significance for secondary caries (OR=1.814, 95 % CI: 0.964-3.415, p-value=0.065). CONCLUSIONS: Dentists value aesthetics and repairability but are aware of shrinkage and experience discolouration. The issue of toxicity and solubility seems to be the least known to dentists. CLINICAL SIGNIFICANCE: Dentists should use RBCs with critical caution due to possible side effects. Despite the undoubted aesthetics of direct composite restorations, it is necessary to remember potential clinical complications such as marginal discolouration or secondary caries.

8.
Microsc Res Tech ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38661289

RESUMO

The aim of this study is to evaluate the surface roughness (SR) and color changes of single-shade and nanohybrid resin-based restorative materials (RBC) after immersion in liquids at different pH values. For RBCs, a total of 120 specimens, 30 for each material, were prepared using 10 mm diameter and 2 mm thick molds. For flowable bulk fill RBC, a total of 40 specimens, 10 for each material, were prepared using 10 mm diameter and 4 mm thick molds (n = 10). After initial color and SR measurements, samples were stored in the liquids for 14 days and all of the measurements were repeated on 14th days. Scanning electron microscopy and atomic force microscopy analyzes were performed in all groups. When SR results are examined; among all liquids, the highest SR value was observed in the Carisma Diamond One (CDO) group, while the lowest SR value was observed in the Omnichroma Flow Bulk (OMF) group (p < .05). When the color changes (ΔE) results are examined; it was observed that CDO group had highest color change and OMF group had the lowest values. It has been observed that among the liquids, the liquids that affect the ΔE values of the materials the most are coffee and cola. When the ΔE values of the subgroups of the materials were examined, there was a statistically significant difference in all subgroups of RBCs (p < .05). While acidic liquids increased the SR of RBCs, coffee more affected the color change of RBCs. RESEARCH HIGHLIGHTS: Clinicians should keep in mind that the RBCs tested may change their surface properties and colors when exposed to various liquids. People who have RBCs should pay attention to the consumption of acidic and highly pigmented liquids.

9.
Technol Health Care ; 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38517820

RESUMO

BACKGROUND: Prosthodontics are often performed to treat patients with malocclusion and dentition defects. However, single prosthodontics cannot properly correct the disharmony of teeth, dental arch and other parts affected by malocclusion, and some patients may have difficulty in recovering the occlusal function due to poor prosthodontics. OBJECTIVE: This study aims to investigate the effect of orthodontics combined with fibre-reinforced composite resin-bonded fixed partial denture (FRC-RBFPD) on anterior dentition defects with minimal vertical intermaxillary space. METHODS: Sixty-two patients with anterior dentition defects with minimal vertical mandibular space admitted to our hospital between March 2021 and May 2023 were enrolled in this study. The participants were divided into the observation group (31 cases) and the control group (31 cases), according to the treatment plan. The control group was treated with traditional therapy, and the observation group was treated with orthodontic combined FRC-RBFPD therapy. Periodontal conditions (periodontal pocket depth [PD], the plaque index [PLI], the sulcus bleeding index [SBI]), levels of inflammatory factors in gingival crevicular fluid (high mobility group box 1 [HMGB1]), myeloid cell triggering receptor-1 (TREM-1), monocyte chemoattractant protein-1 (MCP-1), pain (visual analogue scale [VAS]), the clinical response rate and the incidence of adverse reactions were collected and compared. RESULTS: After 1, 3, 5 and 9 months following treatment, the scores of the PD, PLI, SBI, HMGB1, VAS, TREM-1 and MCP-1 in the observation group were found to be lower than those in the control group (FPD treatment= 352.532, FPLI score treatment= 112.341, FSBI score treatment= 79.479, FVAS score treatment= 96.132, FHMGB1 treatment= 52.532, FTREM-1 score treatment= 64.593, FMCP-1 score treatment= 53.582, and they were all statistically significant P< 0.05). There was a statistically significant difference in the response rate between the two groups (97.77% vs. 80.65%, χ2= 4.026, P= 0.045). No statistically significant difference was observed in the incidence of adverse reactions between the two groups (6.45% vs. 16.13%, χ2= 1.449, P= 0.229). CONCLUSION: Orthodontics combined with FRC-RBFPD shows an ideal restorative effect on patients with anterior dentition defects and minimal vertical intermaxillary space.

10.
Saudi Dent J ; 36(3): 471-479, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38525186

RESUMO

This paper evaluated the influence of different protocols of silver fluoride (SF) pretreatment of artificial carious lesions on the adhesive interface of composite resin restorations and remineralization of deciduous dentin compared to silver diamine fluoride (SDF). Sixty-four deciduous molar teeth were randomly divided into 8 groups (n = 8) according to the restoration time (immediately - IM; 30 days after SDF/SF treatment - 30 D) and treatment before restoration (SDF 38 %; SDF 38 % + potassium iodide - KI; SF 38 %; SF 38 % +KI). After SDF/SF application, teeth in the IM group were restored with self-etch universal adhesive system/composite resin. Samples in the 30D groups were stored in artificial saliva (37 °C) for 30 days before receiving the same restoring protocol. Beams were obtained from all groups and subjected to bond strength tests (µTBS), ultrastructural qualitative analysis (FEG) and mineral analysis (SEM/EDX; Micro-Raman spectroscopy). The µTBS data were subjected to three-factor ANOVA and multiple comparisons (Holm-Sidak method). Bond strength values (MPa) for IM groups were 16.9 ± 2.7 (SDF); 17.6 ± 3.5 (SDF + KI); 16.8 ± 5.5 (SF); 18.4 ± 4.1 (SF + KI); and 14.9 ± 4.2 (SDF); 16.0 ± 5.4 (SDF + KI); 14.1 ± 3.6(SF); 16.4 ± 5.4 (SF + KI) for 30D groups. Bond strength wasn't influenced by the moment of restoration (IM or 30D); the use of KI didn't alter adhesion characteristics; SDF/SF solutions resulted in similar adhesive strength; calcium and phosphate expressions were identified at the interfaces on IM and 30D moments. However, 30D presented qualitative increase in these ions, compatible with remineralization. It was concluded that the adhesion of composite resin restorations in artificial caries lesions of deciduous teeth treated with SDF (38 %) and SF (38 %) had similar effects in vitro; the use of KI or the moment when restorations were accomplished did not influence the adhesion and all tested protocols promoted remineralization of carious dentin.

11.
J Esthet Restor Dent ; 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38500312

RESUMO

OBJECTIVES: This laboratory study evaluated the influence of the fluorescence intensity of composite resins on additional tooth wear and the presence of restorative material in different dental thirds during the retreatment of direct veneers. MATERIALS AND METHODS: The crown dimensions of 60 bovine incisors were reduced to 10 × 8 mm. The teeth were classified according to the fluorescence intensity of the composites: low (LOW) (TPH Spectra), medium (MED) (Opallis), and high (HIGH) (Essentia) groups. The teeth were divided according to the removal methods: conventional (CON) and fluorescence-aided identification technique (FIT). The specimens were scanned (T0), received veneer preparation, and scanned again (T1). After restorations, the composites were removed and the teeth were scanned (T2). Measurement assessments between T1 and T2 were performed to determine additional wear, presence of residual areas, and the average between additional wear and the presence of residual areas. Kruskal Wallis, Mann-Whitney, Friedman, 2-way ANOVA, and post-Tukey tests were performed (α < 0.05). RESULTS: The comparison of composite resins indicated a smaller area of additional wear and greater residue presence in the HIGH group than the LOW group for both techniques in the cervical third. Regarding removal methods, the FIT produced greater additional wear than the CON method for the LOW and MED groups in the middle and cervical thirds. The incisal third exhibited greater additional wear than the other thirds. CONCLUSIONS: Composite resins with high fluorescence intensity removed using FIT had less tooth wear. The incisal third was the most affected area for direct veneer removal procedures. CLINICAL SIGNIFICANCE: A FIT has been proposed for composite resin removal; however, the different fluorescence intensities of composite resins can influence tooth wear caused during this procedure.

12.
Artigo em Inglês | MEDLINE | ID: mdl-38536725

RESUMO

INTRODUCTION: This study aims to investigate the effect of different particle sizes and pressures on the shear bond strength (SBS) and the roughness (Ra) of polyetheretherketone. MATERIALS AND METHODS: A total of 117 polyetheretherketone specimens were fabricated and divided into a control (CN: no air-particle abrasion) and eight pre-treatment groups (air-abraded with 50- or 110-µm Al2O3 particles at 1(A), 1.5(B), 2(C), and 2.5(D) bar). The adhesive, Visio.link was used. Thermal aging was performed. Surface properties, SBS and failure mode were assessed. Data was analyzed by linear regression, Pearson correlation and Dunnett's T3 test for pairwise comparisons (p⟨0.05). RESULTS: The highest and lowest Ra were found in the 110D and CN groups respectively, and the highest SBS results were obtained from the 50B group. Pressure and particle size showed significant difference on the investigated properties (p⟨0.001). Only adhesive failure was observed in the CN, and resin cohesive failure was observed in addition to adhesive failure in the overall study groups. CONCLUSION: The air-borne particle abrasion procedures and the adhesive material combination are critical to the strength of the polyetheretherketone bond. The combination of visio.link with the pre-treatment option of 50-µm Al2O3 particles applied at 1.5-bar pressure delivered the most favorable results.

13.
Dent J (Basel) ; 12(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38534282

RESUMO

The objective was to systematically review studies that evaluated the effect of charcoal-based dentifrices (CbDs) and conventional whitening toothpastes (CWTs) on the color stability (CS) and/or surface roughness (SR) of composite resin (CR). The question we focused on was "Do CbD and CWT affect the CS and/or SR of CR?" Indexed databases were searched without language and time restrictions up to and including May 2023 using different keywords. Original experimental studies were included. The risk of bias (RoB) was assessed using the Quality Assessment Tool for In Vitro Studies. Ten in vitro studies performed on CR were included. The number of CR samples assessed ranged between 18 and 200. In one study, CbDs altered the CS and SR of CR, whereas another study showed no difference in changes in the SR and CS of CR when CbDs were compared with CWTs. One study showed that compared with CWTs, CbDs caused changes in the CS of CR but changes in SR were similar between the two dentifrices. One study showed that CbDs and CWTs improved the overall color and enhanced the SR of CR. Three studies had a high RoB, five had a medium RoB, and two had a low RoB. Compared to CWTs, CbDs appeared to affect the CS of CR, but the SR of CR induced by both dentifrices remained consistent. Further well-designed and power-adjusted studies are needed.

14.
Dent Mater ; 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38458917

RESUMO

OBJECTIVE: To evaluate the effects of an ammonia-based and a water-based silver-containing solutions on bonding performance and matrix-metalloproteinases (MMPs) activity of a universal adhesive to dentin after 1 year of artificial aging. METHODS: Mid-coronal dentin surfaces of 60 sound human molars were exposed and the following groups were formed according to the surface pre-treatment and etching mode of the universal adhesive (Zipbond Universal, SDI) (n = 10): G1) Zipbond in the self-etch mode (ZSE); G2) Riva Star (SDI) applied before ZSE; G3) Riva Star Aqua (SDI) applied before ZSE; G4) Zipbond in the etch-and-rinse mode (ZER); G5) Riva Star applied before ZER; G6) Riva Star Aqua applied before ZER. The specimens were sectioned and subjected to microtensile bond strength (µTBS) test at baseline (T0) and after 12 months (T12) of artificial storage. Scanning electron microscope (SEM) and energy dispersive spectroscopy analysis (EDS) were also conducted. Three additional molars per group were processed for the in situ zymography analysis at T0 and T12. Data were statistically analyzed (p < 0.05). RESULTS: Dentin pre-treatments and aging decreased bonding values, regardless of the etching mode (p < 0.05). No differences in µTBS were observed between the two silver-containing solutions, both at T0 and T12. Riva Star Aqua and etching significantly increased the MMPs activity, independent of the storage period (p < 0.05). SIGNIFICANCE: Dentin surface pre-treatment with silver-containing solutions negatively affects the bonding performances of resin composite restorations placed with a universal adhesive. However, the ammonia-based product Riva Star might show better stability in the long term, due to lower activation of MMPs.

15.
J Dent ; 143: 104917, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38431188

RESUMO

OBJECTIVES: To assess the effects of aging and bleaching procedures on the color stability and surface roughness of a new single-shade composite versus multi-shade composite resins. METHODS: A single-shade composite resin (Charisma Diamond One, CDO) and 3 multi-shade composite resins (Tetric NCeram, Filtek Z350 XT, Clearfil Majesty Posterior) were tested. Thirty specimens of each material were subjected to one of the aging procedures respectively: immersion in distilled water (12 days/37 °C), immersion in coffee (12 days/37 °C), or water thermocycling (10,000 cycles/5-55 °C). All specimens underwent in-office bleaching after aging. Kruskal-Wallis tests and analysis of variance were used for statistical analysis (α=0.05). RESULTS: All materials exhibited a change of color (ΔE00), translucency (RTP), whiteness (WID) and surface roughness parameters (Sa,Sv) after aging and bleaching procedures. CDO showed the highest ΔE00 among all resins with the highest RTP value, regardless of the aging procedures. Immersion in coffee led to the significantly highest ∆E00 values and lowest RTP values for nearly all resins. Positive ΔWID1 (WID(bleaching)-WID(baseline)) values were found in distilled water immersion and thermocycling groups, while negative ΔWID1 values were found in the coffee immersion group for all materials. Besides, positive ΔWID2 (WID(bleaching)-WID(aging)) values were found in all aging groups for nearly all materials. All materials showed an increasing trend in Sa and Sv after bleaching. CONCLUSIONS: CDO showed more pronounced discoloration than multi-shade composite resins. Although the whiteness of all resins increased after bleaching, none was completely restored in the coffee immersion group. Bleaching significantly increased the surface roughness of all materials. CLINICAL SIGNIFICANCE: Charisma Diamond One is more susceptible to discoloration, which may affect its long-term success rate. Bleaching could partially reduce the color change of the composite resins but did not return them completely to their original state. The roughness of the resins increased after bleaching, prompting dentists to repolish them after bleaching.


Assuntos
Café , Resinas Compostas , Água , Diamante , Teste de Materiais , Cor , Propriedades de Superfície
16.
Clin Oral Investig ; 28(3): 207, 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38459231

RESUMO

OBJECTIVE: To compare the clinical performance of a glass hybrid (GH) restorative and a nano-ceramic composite resin (CR) in the restoration of non-carious cervical lesions (NCCLs) of bruxist individuals in a 60-month randomized clinical trial. MATERIALS AND METHODS: Twenty-five bruxist candidates having NCCLs were recruited in this clinical study. The depth, height (cervico-incisal), width (mesio-distal), internal angles of the NCCLs, degree of tooth wear (TWI) and gingival index (GI) were measured. One hundred-and-forty-eight NCCLs were restored either with a GH restorative (Equia Forte Fil) or a CR (Ceram.X One Universal). Modified USPHS criteria was used to evaluate restorations after 1 week and 12, 24, 36 and 60 months. Pearson's Chi-Square, Fisher's Exact and Cochran Q tests were run for analysis. Survival rates of the restorations were compared with Kaplan-Meier analysis (p < 0.05). RESULTS: After 60 months, 97 restorations in 15 patients were examined. The recall rate was 60.0%. Retention rates were 73.5% for CR and 66.7% for GH. A total of 29 restorations were lost (13CR (26.5%), 16GH (33.3%)). There was not a significant difference between tested restoratives in retention (p = 0.464), marginal adaptation (p = 0.856) and marginal discoloration (p = 0.273). There was no relationship between internal angle, depth, height or width and retention of the GH or CR restorations (p > 0.05). The increase in retention loss and marginal discoloration of both restorations over time were significant (p < 0.001). Sensitivity or secondary caries were not detected after 60 months. CONCLUSION: GH and nano-ceramic CR showed similar clinical performances in NCCLs after 60 months in patients with bruxism. CLINICAL SIGNIFICANCE: After 60 months, CR and GH materials showed clinically acceptable performances in restoration of NCCLs in patients with bruxism.


Assuntos
Bruxismo , Cárie Dentária , Humanos , Restauração Dentária Permanente , Colo do Dente/patologia , Resinas Compostas , Cárie Dentária/patologia , Adaptação Marginal Dentária , Cimentos de Resina
17.
J Dent ; 144: 104930, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38471581

RESUMO

OBJECTIVES: This 24-month, double-blind, split-mouth randomized clinical trial aimed to compare the retention rates of a preheated thermoviscous composite resin (PHT) compared to a non-heated composite resin (NHT) in non-carious cervical lesions (NCCLs). METHODS: A total of 120 restorations were restored on NCCLs using a preheated (VisCalor bulk, Voco GmbH) and a non-heated (Admira Fusion, Voco GmbH) composite resins with 60 restorations per group. A universal adhesive in the selective enamel conditioning was applied. In the PHT group, composite was heated at 68 °C for using a bench heater. In the NHT group, no heating was employed. Both restorative materials were dispensed into caps and inserted into the NCCLs. The restorations were evaluated at baseline, 6, 12, 18, and after 24 months of clinical service using the FDI criteria. Statistical analysis was performed with Kaplan-Meier estimation analysis for retention/fracture rate and Chi-square test for the other FDI parameters (α=0.05). RESULTS: After 24 months 108 restorations were assessed. Seven restorations were lost (two for PHT group and five for NHT group), and the retention rates (95 % confidence interval [CI]) were 96.7 % (81.5-99.9) for PHT group and 90.8 % (81.1-96.0) for NHT group, with no statistical differences between them (p > 0.05). The hazard ratio (95 % CI) was 0.52 (0.27 to 1.01), with no significant difference within groups. In terms of all other FDI parameters that were assessed, all restorations were deemed clinically acceptable. CONCLUSIONS: Both composites showed high rates of retention rates after 24 months. CLINICAL SIGNIFICANCE: The clinical performance of the new preheated thermoviscous was found to be as good as the non-heated composite after 24-month of clinical evaluation in non-carious cervical lesions. REGISTRATION OF CLINICAL TRIALS: RBR-6d6gxxz.


Assuntos
Resinas Compostas , Restauração Dentária Permanente , Temperatura Alta , Colo do Dente , Humanos , Resinas Compostas/química , Resinas Compostas/uso terapêutico , Restauração Dentária Permanente/métodos , Feminino , Método Duplo-Cego , Masculino , Colo do Dente/patologia , Adulto , Pessoa de Meia-Idade , Materiais Dentários/química , Falha de Restauração Dentária , Adulto Jovem , Sensibilidade da Dentina , Cimentos de Resina/química , Seguimentos , Estimativa de Kaplan-Meier , Resultado do Tratamento , Propriedades de Superfície , Erosão Dentária/terapia
18.
Heliyon ; 10(6): e27735, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38509902

RESUMO

Objectives: This retrospective study aimed to assess the performance of posterior composite resin restorations (PCRRs) and evaluate the influence of patient-specific factors on restoration outcomes. Methods: A total of 189 PCRRs were examined in 54 patients, with evaluations based on Modified USPHS criteria. Patient-specific factors were analyzed. Statistical analyses, including chi-square tests, independent samples t-tests, and ANOVA tests, were conducted. Results: Patients aged over 50 exhibited higher DMFT averages and a higher rate of unsuccessful restorations. Despite higher DMFT scores in females, gender doesn't significantly impact restoration outcomes. Secondary caries correlated with.plaque scores, significantly affecting restoration survival. Marginal adaptation, retention deficiencies, and secondary caries were primary causes of failure. Multi-surface restorations faced higher failure risk due to elevated plaque scores. Class-V restorations showed a higher failure rate, challenging the number of surfaces and longevity correlation. Conclusions: This study identified key factors influencing posterior composite resin restorations-(PCRRs) in patients over 50, including higher DMFT averages and more unsuccessful restorations. No significant difference was found between brushing; frequency and DMFT rates, possibly due to the absence of non-brushers. Secondary caries; correlated with elevated plaque scores, impacting restoration survival. Primary causes of; failure included marginal adaptation issues, retention deficiencies, and secondary caries, with multi-surface restorations facing a higher risk. However, tooth vitality, beverage and acidic food consumption, and oral hygiene habits did not significantly affect PCRR outcomes. Clinical significance: Patient-specific factors significantly impact PCRRs' long-term performance. Dentists must tailor strategies, emphasizing regular monitoring and preventive measures for extended survival.

19.
J Contemp Dent Pract ; 25(1): 29-34, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38514428

RESUMO

AIM: To evaluate the effect of thermo-mechanical cycling (TMC) on fracture resistance of different computer-aided design/computer-aided manufacture (CAD/CAM) crowns. MATERIALS AND METHODS: A total of 42 CAD/CAM crowns were fabricated on epoxy resin maxillary first premolar teeth and divided into three groups (n = 14) according to the material used: IPS e.max CAD (Ivoclar Vivadent) lithium disilicate (LD), Vita ENAMIC (VE) (VITA Zahnfabrik), Tetric CAD (Ivoclar Vivadent). Also, each group was subdivided into two equal subgroups according to TMC (n = 7). Subgroups (O) without TMC and subgroup (W) with TMC (5-55°C, 30 second, 75,000 cycles). All samples in each group were cemented with a universal bond (Tetric N bond universal) and adhesive resin cement (Variolink Esthetic DC) (Ivoclar Vivadent). Subsequently, the samples were loaded to failure in a universal testing machine at a crosshead speed of 1 mm/min, and the fracture pattern and the fracture resistance in each group were recorded. RESULTS: Fracture resistance was analyzed by one-way analysis of variance (ANOVA) test, followed by Tukey's post hoc test for pairwise comparison. Fracture resistance showed a significant difference between the tested groups before and after TMC; IPS e.max CAD has the highest value (1233.35 ± 97.72, 1165.73 ± 199.54 N) followed by Tetric CAD (927.62 ± 42.5, 992.04 ± 53.46 N) and Vita ENAMIC has lowest value (506.49 ± 74.24, 354.69 ± 90.36 N). CONCLUSION: Thermo-mechanical cycling affected the fracture resistance of both polymer-based CAD/CAM crowns. CLINICAL SIGNIFICANCE: For dental practitioners, both IPS e.max CAD and Tetric CAD can be used clinically for posterior teeth, providing satisfactory results and resistance to fracture. How to cite this article: Elmokadem MI, Haggag KM, Mohamed HR. Effect of Thermo-mechanical Cycling on Fracture Resistance of Different CAD/CAM Crowns: An In Vitro Study. J Contemp Dent Pract 2024;25(1):29-34.


Assuntos
Resinas Acrílicas , Resinas Compostas , Odontólogos , Poliuretanos , Papel Profissional , Humanos , Estética Dentária , Porcelana Dentária , Cerâmica/química , Coroas , Desenho Assistido por Computador , Teste de Materiais , Análise do Estresse Dentário , Falha de Restauração Dentária
20.
J Prosthodont Res ; 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38479888

RESUMO

PATIENTS: This case report presents a minimally invasive approach to replace a missing mandibular lateral incisor using a dual-injection molding technique with flowable composite resins. Integrated with a comprehensive digital workflow, this method achieves a structurally and esthetically biomimetic, bi-layered prosthetic solution. A 34-year-old woman with congenital absence of a mandibular lateral incisor was successfully rehabilitated using a direct composite resin-bonded fixed partial denture (RBFPD). DISCUSSION: Two specialized three-dimensional (3D)-printed flexible indices stabilized by a custom-designed 3D-printed rigid holder were employed to ensure the meticulous injection molding of flowable composite resins formulated to emulate the inherent chromatic gradations between dentin and enamel. The inherent flexibility of the indices, combined with the holder, facilitated accurate and seamless adaptation to the complex morphological features of the dental arch, thereby mitigating the challenges commonly associated with rigid 3D-printed resin indices. CONCLUSIONS: The bilayered direct composite RBFPD using 3D printed flexible indices prepared with a full digital workflow has several advantages over other dental prosthetic solutions, including noninvasiveness, cost-effectiveness, biomimetic esthetics, repairability, and shortened treatment times. Although the initial results are promising, further longitudinal studies with larger patient cohorts are required to confirm the long-term efficacy of this approach.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...